Akemi Skeleton Gun — Manual Cartridge Dispenser for Akepox & Akemi Adhesives
The Akemi Skeleton Gun is a manual cartridge applicator for Akemi's family of cartridge-packaged adhesives, including Akepox cartridges and the Akemi knife-grade chemistry that ships in cartridge form. Skeleton-frame design lets the fabricator see the cartridge through the body for visual control of dispensing rate. It is the standard accessory tool for any Akemi cartridge user — required to dispense the adhesive with controlled, repeatable force.
Features
- Manual cartridge dispenser for Akemi adhesive cartridges
- Skeleton-frame design — visual control of cartridge level
- Required accessory for Akepox and Akemi cartridge users
- Compatible with standard Akemi cartridge sizes (use with Akemi adapters where the cartridge differs)
- Mechanical operation — no battery or air supply
- Premium German tool from Akemi
| Property | Detail |
|---|---|
| Brand | Akemi |
| Part Number | 10665 |
| Product | Skeleton Gun for Akepox / Akemi cartridges |
| Type | Manual cartridge applicator (skeleton frame) |
| Compatibility | Akemi adhesive cartridges (use Akemi 50 mL adapter for smaller cartridges) |
| Operation | Mechanical hand trigger |
- Inspect the gun before each use; verify the plunger and trigger move freely.
- Open the gun and insert the cartridge so it seats fully in the frame.
- Cut the cartridge tip and install the static mixer per the cartridge manufacturer's instructions.
- Squeeze the trigger to dispense; release to stop flow.
- After use, remove the cartridge and wipe the gun clean of adhesive residue.
- Replace the static mixer for each new cartridge to prevent cured-resin blockage.
- Read the product Safety Data Sheet (SDS) before opening the container.
- Wear chemical-resistant gloves, ANSI Z87 eye protection, and appropriate respiratory protection per the SDS.
- Use only with adequate ventilation. Solvent and resin-based products may release VOCs during application and cure.
- Keep out of reach of children and pets.
- Store in a cool, dry place in the original sealed container; follow the SDS storage temperature range.
- Dispose of empty containers and unused product per local hazardous-waste regulations.
- Inspect the static mixer for cured residue before each new cartridge — a blocked mixer can fail under pressure.
Always read the product Safety Data Sheet (SDS) before use. Wear chemical-resistant gloves and eye protection. Use only with adequate ventilation. Follow all local regulations for storage and disposal of chemical products.