Skip to Content

Akemi Skeleton Gun — Manual Cartridge Dispenser for Akepox & Akemi Adhesives

The Akemi Skeleton Gun is a manual cartridge applicator for Akemi's family of cartridge-packaged adhesives, including Akepox cartridges and the Akemi knife-grade chemistry that ships in cartridge form. Skeleton-frame design lets the fabricator see the cartridge through the body for visual control of dispensing rate. It is the standard accessory tool for any Akemi cartridge user — required to dispense the adhesive with controlled, repeatable force.

Features

  • Manual cartridge dispenser for Akemi adhesive cartridges
  • Skeleton-frame design — visual control of cartridge level
  • Required accessory for Akepox and Akemi cartridge users
  • Compatible with standard Akemi cartridge sizes (use with Akemi adapters where the cartridge differs)
  • Mechanical operation — no battery or air supply
  • Premium German tool from Akemi
PropertyDetail
BrandAkemi
Part Number10665
ProductSkeleton Gun for Akepox / Akemi cartridges
TypeManual cartridge applicator (skeleton frame)
CompatibilityAkemi adhesive cartridges (use Akemi 50 mL adapter for smaller cartridges)
OperationMechanical hand trigger
  1. Inspect the gun before each use; verify the plunger and trigger move freely.
  2. Open the gun and insert the cartridge so it seats fully in the frame.
  3. Cut the cartridge tip and install the static mixer per the cartridge manufacturer's instructions.
  4. Squeeze the trigger to dispense; release to stop flow.
  5. After use, remove the cartridge and wipe the gun clean of adhesive residue.
  6. Replace the static mixer for each new cartridge to prevent cured-resin blockage.
  • Read the product Safety Data Sheet (SDS) before opening the container.
  • Wear chemical-resistant gloves, ANSI Z87 eye protection, and appropriate respiratory protection per the SDS.
  • Use only with adequate ventilation. Solvent and resin-based products may release VOCs during application and cure.
  • Keep out of reach of children and pets.
  • Store in a cool, dry place in the original sealed container; follow the SDS storage temperature range.
  • Dispose of empty containers and unused product per local hazardous-waste regulations.
  • Inspect the static mixer for cured residue before each new cartridge — a blocked mixer can fail under pressure.

Always read the product Safety Data Sheet (SDS) before use. Wear chemical-resistant gloves and eye protection. Use only with adequate ventilation. Follow all local regulations for storage and disposal of chemical products.